Low thermal resistance
No leakage
Good thermal stability
Good ductility
The corrosion on AI/CU is not significant
Project | Technical indicators | Testing instrument | Testing standards |
---|---|---|---|
Color | Silver | Visual | - |
Specifications(mm) | -- | Digital caliper | ASTM D 5947 |
Thickness(mm) | 0.1-0.5 | Digital caliper | ASTM D 374 |
Density(g/cc) | 7.2(±0.2) | ZMD-2 Electron Density Meter | ASTM D 792 |
Melting point(℃) | 140(±10) | Constant temperature electric heating plate | GB/T 1425-2021 |
Tensile strength(Mpa) | ≥3(@50psi) | Compression Tester | ASTM D 575 |
Compression ratio(%) | ≥20(@50psi) | Compression Tester | ASTM D 575 |
Vertical resistance(Ω) | ≥10-3 | Megohmmeter | ASTM D 257 |
Surface resistance(Ω) | ≥10-3 | Megohmmeter | ASTM D 257 |
Thermal resistance(℃·cm2/W) | ≤0.04(@50psi) | LW-9389 Thermal Conductivity Tester | ASTM D 5470 |
Operating temperature (℃) | -40~160 | XB-OTS-150D-C Programmable Thermal Shock Chamber | IEC 60068-2-14 |
Production equipment and testing equipment to ensure high quality.
Power prodcution and processing plant,specializing in customizing products.
Intimate after-sales team,respond quickly to each customers queston.